HausenLab
STRUCTURAL REINFORCEMENT

Structural Reinforcement in Istanbul

Earthquake-resilient, future-safe.

From seismic performance analysis to carbon fiber reinforcement, from jacketing to column-beam repair — we bring your building into compliance with the current seismic code.

Scope

What we do in this service.

Every item is listed in a written contract. No surprises, clear boundaries.

  • Seismic performance analysis (DBYBHY 2018)
  • Carbon fiber (CFRP) reinforcement
  • Steel jacketing and steel construction
  • Shotcrete (sprayed concrete) application
  • Column and beam repair
  • Foundation repair and micropile reinforcement
  • External facade jacketing (thermal + structural)
  • Building inspection and reporting
Process

How we work.

  1. 01

    Site Inspection

    The building is inspected on site and concrete samples are taken.

  2. 02

    Performance Analysis

    Static and dynamic analysis determines the current performance.

  3. 03

    Reinforcement Design

    Carbon fiber, steel, or jacketing — the most suitable method is designed.

  4. 04

    Execution

    Reinforcement is applied step by step without disrupting site activity.

  5. 05

    Test & Certification

    Post-application tests are performed; an engineer-certified report is delivered.

Cost Calculator

Instant estimate.

Choose parameters, see the estimated range instantly. The binding quote is set after the on-site survey.

Instant Estimate

Structural Reinforcement Cost Calculator

500
100 3.000
4
1 10
Estimated Range
₺1.905.200₺2.424.800
Excluding VAT, at average market rates
This price includes:
  • Carbon Fiber (CFRP) application labor
  • Building-inspection-approved materials (Sika, MasterBrace, etc.)
  • Engineer supervision and reporting
  • Application certificate (PDF + printed)
  • DBYBHY 2018 performance analysis report
Not included in this estimate:
  • Repair of interior damage
This is an approximate estimate; the binding quote is given after the on-site survey.
Request free survey at this estimate
FAQ

Answers to your questions.

More to ask? Write to us directly.

  • Can reinforcement happen without vacating the building?

    In most cases, yes — column/beam reinforcement and jacketing can proceed without vacating floors. Heavy foundation interventions may require temporary vacating.

  • Carbon fiber or steel jacketing — which is better?

    There is no single right answer. It depends on building type, floor count, existing damage level, and budget. After the analysis, our team recommends the most suitable method.

  • Can I obtain occupancy after reinforcement?

    Yes. When reinforcement is carried out under a building-inspection-approved process, the existing occupancy is preserved or renewed if needed via the municipal report.

  • Can I get only the performance analysis?

    Of course. Our 'rapid assessment' module also delivers just the analysis report; you decide on reinforcement.

Related Guide
Structural Reinforcement Guide: Carbon Fiber, Steel, and Concrete Jacketing
Seismic reinforcement in Istanbul: carbon fiber (CFRP), steel jacketing, concrete jacketing, and column reinforcement methods. A DBYBHY 2018-compliant process with engineer-certified reporting.10 min

Structural Reinforcement free survey.

Let us visit the site, take measurements, and leave a written quote. Every detail is shared in writing before signing.